Given that an RCD may take up to 0.3 seconds (300 ms) to disconnect it would appear at first glance that some disconnection times in Table 41.1 may not be achievable, for example, the maximum disconnection time for some final circuits on a TT earthing system is 0.2 seconds (200 ms), as shown in Table 3. However, a note under the table indicates that earth faults are of negligible impedance and it follows that disconnection times would be commensurately higher since a value of, for example, a residual current of 60 mA would be expected to provide a disconnection time of 150 ms and 40 ms (0.04 seconds) for a residual current of 150 mA, as shown in Table 2. Therefore, an operating time of 300 ms would be considered acceptable for a TT earthing system. This may make it necessary to refer to manufacturer’s data relating to the RCD under test and, in many cases may mean that the test instrument manufacturer may need to be consulted to determine how best to configure the instrument prior to testing.

The presence of SPDs in an installation shall be indicated by an information notice at or near the relevant distribution board(s). It is essential to understand the limitations of the test instrument and product standard requirements when testing RCDs using the available RCD Type settings on the test instrument. Higher Risk Residential Buildings are assumed to be residential buildings over 18 m in height or in excess of six storeys, whichever is met first. Should this building incorporate a business premises on the ground floor for example then this too could fall under this requirement. Before we look at testing RCDs, it is worth pointing out that the requirements for selection and erection of RCDs have been amended. Regulation 531.3.3 of BS 7671:2018+A2:2022 states that the appropriate RCD shall be selected according to the presence of DC components and AC frequencies. Further, Type AC RCDs shall only be used to serve fixed equipment, where it is known that the load current contains no DC components.Many of the issues encountered when testing RCDs are down to user error as opposed to faulty RCDs. It may come as a surprise to some, but RCD testing should be carried out at the RCD with the outgoing wiring disconnected. However, this is not usually done. The usual live working procedures must be considered, and suitable precautions taken when carrying out work near live parts. This essential update to the IET Wiring Regulations forms the national standard to which all new electrical installations and additions, and alterations to existing electrical installations in the UK are to comply. It is important tobecome familiar with the changes. The days of selecting an RCD according to current rating and rated residual current alone are gone, now the designer must select the RCD according to the nature of the residual fault currents, including pulsed or steady-state DC components expected to be present.

This is still a consideration for the designer of the installation with Regulation 531.3.2. To achieve this, they should ideally ensure there is no more than 30% of the rated residual operating current due to protective conductor current and/or earth leakage currents (i.e. 9mA for a 30mA device). There is a new indent (ii) to consider the use of RCBOs as opposed to split load arrangements for this purpose.Each manufacturer’s instrument is different but changing the RCD Type is usually selected by pressing the relevant ‘function’ button on the instrument and the RCD Type symbol will change accordingly: see Figure 2. Most instruments will include a function to test general non-delayed and S Type time-delayed Type AC and Type A RCDs, some test instruments may also include a facility for testing other Types such as Type B RCDs. There may be some equipment however that would show false readings at this test. It is therefore important that manufacturer’s instructions be consulted and if necessary the equipment disconnected during this 250 V DC test. However following the reconnection of such equipment, a test at 250 V DC shall be carried out between live conductors and the protective conductor, which should be connected to the earthing arrangement. The result of this test shall be at least 1 MΩ. Generally, an RCD either works or it doesn’t and, in essence, the test is to prove that the RCD is functional and is not intended to confirm that it still performs as per the relevant product standards and manufacturers requirements. RCD testing required by product standards is carried out by the manufacturer and is called type testing. that all warning notices and relevant safety signs comply with the relevant standards for safety signage, which, in any case, would be required to comply with the Health and Safety (Safety Signs and Signals Regulations) 1996:

Figure 2 Examples of the label required by proposed Regulation 514.13.1, when the label is not part of an earthing/bonding clamp to BS 951These proposed changes are also reflected in proposed updates to Appendix 7. In addition, the informative Appendix 7 Harmonized cable core colours includes a new item 8: Colour codes for diagrams and specifications, which summarizes (in Table 7F) the BS 7645 colour codes, and recommends that they are used, where required, to identify conductors in operation and maintenance information, such as wiring diagrams and termination schedules. Proposed new Regulation 514.9.2 the use of Pink for the identification of a conductor whose sole purpose is a functional earth, along with the alphanumeric designation FE, was implemented by Corrigendum 2018, to align with the harmonized standard BS EN 60445:2017 Basic and safety principles for man-machine interface, marking and identification. Identification of equipment terminals, conductor terminations and conductors. BS EN 61009-1:2012+A13:2021 Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs). General rules. David Garrett, Product Management Manager at Deta, says “This is a reminder that the regulations affecting consumer units become mandatory on 28th September, and that all designers, developers and installers should be mindful that they need to be compliant from this date. Deta can assist in providing related information and product solutions to match your needs.”